Psi Logo Division Header
Piping Specialties PSI Controls Div Psi Controls Button PSI Services Div
News Specials Downloads Contact Us Links Spacer
Header Bottom Border
C o n t r o l   P a n e l   D e s i g n

PLC's
Single Loop PID Controls
User Interfaces

I n s t r u m e n t a t i o n
Pneumatic
Electronic
Calibration
Repair
Installations
Startups
Troubleshooting
Upgrades
V a l v e s  &  C y l i n d e r s
Inspection
Testing
Repair

Automation
Reconditioning

C o n t r o l   S y s t e m
D e s i g n  &  S e t u p

Complete system design & setup

C o m p u t e r i z e d   M a i n t e n a n c e
S y s t e m   I n t e g r a t i o n

Integration
SAP Bill of Materials (BOMs)
Loop Data Bases

S y s t e m   D o c u m e n t a t i o n

Loop Component Labeling
Storeroom Inventory
Loop Sheets

P r e v e n t i v e   M a i n t e n a n c e
Pneumatic
Electronic
Mechanical
Scheduling
Maintenance
Service Agreements

S u p p l e m e nt a l   S u p p o r t
Work with customer's employees to
provide any additional support needed
IMPORTANT INFORMATION FROM OUR TECHNICIANS

PSI CONTROLS Service Department

Recent economic conditions have forced industry to run leaner operations. Let the PSI CONTROLS service department fill the voids left by those cutbacks. Whatever your needs — simple field installations, calibration, troubleshooting, repair, design, setup, or additional manpower for your onsite professionals — our service team is ready to meet your needs.

Your full service instrumentation source. Photo(281pxwide171pxhigh)

 
power walkdown
Predictive Maintenance Inspection
– Power Walkdown

Severe service valves, and the equipment they protect, represent significant capital investments in your plant. To protect those investments and the performance of your facility, we offer a power walkdown — an inspection of your critical valves using contemporary technology and technical experience.

When performing a power walkdown, our experienced inspectors use a proven process to:

  • Capture valve performance data, such as temperatures along the bore path.
  • Analyze the information gathered from the valve performance data and visual inspection.
  • Report findings on our Unit Walkdown Report and, upon request, our Power Walkdown Thermography Inspection Report.
  • Recommend action to repair or replace underperforming valves.

In addition to capturing thermal efficiency readings during the predictive maintenance inspection, we also perform a visual inspection to ensure that:

  • Valves are installed with the correct flow direction
  • Stem scribe lines are accurately aligned or that the valve is fully closed
  • Appropriately designed valves are installed in the proper application
  • The actuator is mounted correctly
  • Joints, body and packing are void of leaks

While suggestions and on-the-spot test results can be given, a more thorough, analytical report is provided. This report provides performance data so crucial issues can be quickly remedied, while non-urgent action can be budgeted and scheduled. A single report can show the results of several walkdowns, profiling individual valve performance and identifying trends. Our recommended action to replace a valve is validated with statistical data within the report.  more about Power Walkdown

Contact us today for substantial cost savings, higher system reliability and increased personnel safety at your plant.